EOCR (Electronics Over Current Relay) is a Motor Protection Relay to protect your electric motor form burn out due to frequent and common problems.

 

MCU Based

3 Integral Current Transformers

Over-current, Under-Current, Phase Loss, Phase

Unbalance, Phase Reversal, Locked Rotor Protection

Digital Ammeter & Trip cause indication

Selectable Trip Time-Current Characteristics

Independently Adjustable Starting Trip Delay and Operating

Trip Time

+ Load Alerting Function → EOCR-3DE

+ Ground Fault Protection → EOCR-3EZ 


Parameter Table


Protection

EOCR-3DE

EOCR-3EZ

Protective Item

Trip Time

Protective Item

Trip Time

Over-current

O-TIME

Over-current

O-TIME

under-current

0.5~30sec

Under-current

0.5~30sec

Phase Loss

3 sec

Phase Loss

3 sec

Phase Unbalance

8 sec

Phase Unbalance

8 sec

Phase Reversal

0.1~0.3 sec

Phase Reversal

0.1~0.3 sec

Locked Rotor

D-TIME

Locked Rotor

D-TIME

-

-

Ground Fault

0.05~10 sec



Specification

Model

EOCR-3DE

EOCR-3EZ

Over Current Setting Range

Refer Table #1

Ground Fault Current Setting

-

0.02 ~ 3A

Alert Setting

50 ~ 100% / OFF

-

Start Delay Time Setting (D-TIME)

1 ~ 200 Sec

Trip Delay Time Setting (O-TIME)

INV

1 ~ 30

DEF

0.2 ~ 30 Sec

Control Voltage


24VAC/DC, 110VAC±15%, 220VAC±15%

Output Relay

OL

2-SPST

1-SPST

AL/GR

AL Relay

Ground Fault Relay

Rating

3A/250VAC Resistive

Time Characteristic

In/”tc ”mode

Inverse (See Curve-1)

dE/”tc ”mode

Definite (See Curve-2)

Troubleshooting / Trip Indication

LED Display (SSD+LED)

Current Sensing

3-CT

Mounting

35mm Din-rail


Table #1. Current Range


Current Setting Range (Amps)

Number of Conductors thru CT windows

Extermal CT Ratio

Setting of CT Ratio

Remark

0.5 ~ 60A

1

-

OFF(Mode : --)

Wide Range

0.25 ~ 3.0A

2

-

2t


0.1 ~ 1.2A

5

-

5t


1 ~ 12A

1

10 : 5

10


1.5 ~ 18A

1

15 : 5

15


2.0 ~ 24A

1

20 : 5

20


2.5 ~ 30A

1

25 : 5

25


3.0 ~ 36A

1

30 : 5

30


4.0 ~ 48A

1

40 : 5

40


5 ~ 60A

1

50 : 5

50


6 ~ 72A

1

60 : 5

60


7.5 ~ 90A

1

75 : 5

75


10 ~ 120A

1

100 : 5

100


12 ~ 144A

1

120 : 5

120


15 ~ 180A

1

150 : 5

150


20 ~ 240A

1

200 : 5

200


25 ~ 300A

1

250 : 5

250


30 ~ 360A

1

300 : 5

300


40 ~ 480A

1

400 : 5

400


50 ~ 600A

1

500 : 5

500


60 ~ 720A

1

600 : 5

600


75 ~ 900A

1

750 : 5

750


80 ~ 960A

1

800 : 5

800



Previous: 
Next: 

Subscribe to get exclusive updates and offers!

QUICK LINKS

PRODUCTS

CONTACT

 info@greenwich.com.cn
 +86-577-62713996
 Jinsihe Village, Liushi Town, Yueqing, Zhejiang, China
Copyright © 2024 GWIEC Electric. All rights reserved.  Supported by leadong.com    Sitemap